"Heyuan Liji" is a joint venture between Heyuan Biotechnology (stock code: 688238) and Liji Biotechnology, specializing in the "Liji Biotechnology" and "Life-ilab" reagent brands
click to copy
product description
The tricolor pre stained protein marker (2.7-40KD) contains 9 highly purified and pre stained recombinant proteins (2.7, 4.2, 6.5, 10, 15, 20, 25, 30, 40kDa). Among them, the 40kDa band is orange red, the 10kDa band is green, and the remaining bands are blue. Its apparent molecular weight was calibrated using thermo26632 non pre stained protein molecular weight standard, making it suitable as a protein molecular weight standard for SDS-PAGE and Western blotting.
This product has been prepared in 1 × SDS-PAGE sample buffer and can be used directly without boiling, dilution, or adding reducing agents. According to the size of the sample well, 5-10 μ L of protein can be observed very clearly during electrophoresis, after electrophoresis, and after membrane transfer each time.
ordering information
product name | item number | specifications |
Tri color pre stained protein marker (2.7-40KD) | AP13L032 | 100 μL |
Tri color pre stained protein marker (2.7-40KD) | AP13L033 | 5*100 μL |
Transportation and storage
Blue ice transportation. Short term storage at 4 ℃, valid for 2 months- Long term storage at 20 ℃, with a shelf life of 36 months.
usage method
After thawing at room temperature, gently mix or use a pipette to slowly blow evenly, avoiding boiling.
2. Take 5 μ L of this product and test sample for polyacrylamide gel electrophoresis at the same time. It is recommended that the laboratory conduct pre experiments based on their own experimental conditions and habits when using this product for the first time to determine the appropriate sample size, which can save costs and obtain better experimental results.
3. Unused color pre dyed protein molecular weight standards should be stored according to storage conditions and can be stored at 4 ℃ for 2 months.
Pre stained protein molecular weight standard
Gel 18% Tricine Blot(400mA 15min)
matters needing attention
1. This product is only for scientific experimental research and should not be used in clinical diagnosis, treatment, or other fields.
2. Pay attention to the electrophoresis time, as low molecular weight proteins may swim out of the protein gel front.
3. When performing Western blot, attention should be paid to the specificity of small molecules, especially for bands smaller than 3kDa, which can easily pass through the membrane. Additionally, it is recommended not to add SDS to the transfer solution. If it is necessary for the experiment, the concentration of SDS should not exceed 0.02% -0.04%.
4. Pre stained proteins have different apparent molecular weights in different buffer systems. If non pre stained proteins are calibrated in advance in this buffer system, the protein molecular weight can be roughly determined.